MF-112 AND MF-116 - Compact Waveguide Loads... Abstract
Return to Memo list
ALMA MEMO #494
MF-112 AND MF-116: Compact Wavguide Loads And
FTS Measurements At Room Temperature And 5 K
A. R. Kerr (1), H Moseley (2), E. Wollack
(2), W. Grammer (3),
G. Reiland (3), R. Henry (2), K.P. Stewart (4)
1 National Radio Astronomy Observatory,
Charlottesville, VA 22903.2 Goddard Space Flight Center, Greenbelt, MD 20771.
3 National Radio Astronomy Observatory, Tucson, AZ 85721.
4 Naval Research Laboratory, Washington, DC 20375
2004-05-14
In many applications it is convenient to have a compact waveguide load which is well matched but occupies a minimum of space. In this memo we describe measurements on compact WR-10 and WR-3.7 waveguide loads of three configurations, and also Fourier transform spectrometer (FTS) measurements on samples of the Eccosorb MF-112 and MF-116 absorbing materials used for these loads. The measurements were made at room temperature and 4 K. From the FTS measurements, the attenuation constant, effective characteristic impedance and effective dielectric constant in the frequency range 400 GHz -2.5 THz are deduced.
View a pdf version of ALMA Memo #494.