Source Search

Select the VLA catalog in the catalog tree at the left-hand side and view the main editing window to the right. Source names follow J2000 IAU naming convention (i.e., truncated 10-character Jhhmm+ddmm) and aliases can be found by hovering over Aliases or by viewing the source properties (by clicking on the edit icon Edit Source). To find source 3C279 it may take a while, even if you know this source is J1256-0547 (note the capital "J") in the IAU convention. Entering 3C279 (note the capital "C") in the source search tool in the upper part of the left-hand side column will search the selected source catalog for the source name in that catalog. If the "Search Aliases As Well" tick-box is not ticked, the search will only be matching for the name entered in the catalog (for VLA these are IAU names, but in your personal catalog you could have named your source 3C279 or "Skippy", etc); it then will only find this source in the VLA source catalog if J1256-0547 is entered. Therefore the aliases tick-box is by default ticked, but because searching is done on partial strings you may want to remove the option if you otherwise expect many matches (e.g., if you are looking for your source matching on the string "C" and don't want all 3C-sources to appear).

Because the search is performed on a partial string, searching for "-" (a minus sign) in the VLA catalog, for example, will return a 16 page table with all VLA calibrators with negative Declination (J2000), plus some extra sources with a minus sign in the name if you left the "Search Aliases" checked. A search on 1331+ will return 3C286 (as J1331+3030). Searches should not be case sensitive, but sometimes weird returns happen if lower cases are supplied; use upper case (J, B, C) for the standard VLA calibrators and their aliases. Two wild-cards are allowed: "?" and “*".  They have the usual meaning of a single arbitrary character and any number of arbitrary characters, respectively. However, they are only useful between two other characters in the search string, as the search on *string* is automatically performed as a search on an empty search string which returns the entire catalog.

A source may also be obtained using the External Search if it is unknown to any of the existing catalogs. This search will be performed on the names, including aliases, in the SIMBAD database, using the same search and character rules.

Advanced Search

The Advanced Search (Figure 2.5) is used to search in an existing, selected catalog for other criteria than source name or alias. A common example is to search for a nearby calibrator at a position of your source of interest. This Advanced Search will bring up a dialog box in the main editing window containing various search parameter options. In that window, select the catalog(s) in which the search should be performed, and select the table(s) with the required parameters by checking the upper left tick-box of the relevant tables. Above the search parameter tables, you can select "All" or "None" catalogs and subsequently toggle individual catalogs. Table options and editing fields become active only when you select to use it. More than one catalog and more than one parameter table may be selected; the search interprets additional parameters as an AND condition. To perform the search, click the "Search" button below the parameter fields. Be patient, as searching can take a while; please do not continue clicking with the mouse button until the search operation has finished.

Advance Search Parameters
Figure 2.5: The various search parameters of Advanced Search.
Advanced Search Parameters
Cone Search
  • This parameter searches a radius, entered in degrees, around a position (J2000) or around the position of a source selected from any of the source catalogs by using the Select Source button (which brings up a dialog box to select a source from one of your catalogs). The resulting table will be sorted in increasing distance from the position; the table can be resorted if desired (by clicking table headers that turn orange).
  • Positions are interpreted as decimal degrees if not supplied as, e.g., 1h 37m [41.3s] for R.A. and [+]33d 9' [35"] for Dec.; not supplied as a group of three numbers separated by a space or a colon, or otherwise not recognized as a sexagesimal entry.
  • To activate the interpretation in the fields entered, click with the mouse button somewhere outside the boxes to validate the input. Always check the coordinates after entering each position or after pressing the Search button; it will replace your values with the interpretation of the validation procedure. You should check these values; the validation procedure will always be able to convert your entered values with these rules, but you are the only one to know whether the validation conversion is sensible.
  • With the 1.31 update you now have the ability to generate a Sky Map of sources based upon the RA, Dec, and Search Radius parameters entered into the Cone Search fields. Please see the entry below on the 1.31 User Interface Updates.
Search By Calibrator Code
  • This parameter allows a search for sources with a closure phase structure code (P, S, W, X) equal or better than the code selected for a certain observing band and VLA array configuration.
      • This Calibrator Code is not to be confused with the the AIPS calibrator code (A, B, C, T) indicating a positional accuracy. Consult the VLA calibrator manual for more information on the definition of these codes and positional accuracy.
Search By Flux Density

This parameter searches for flux densities above the given limit in the selected observing band. This is of course only useful when flux densities are included in the catalog(s) selected.

Search By Name

This is the same search action with the same string rules as for the string entered in the top search tool in the left-hand side column, with the difference that here more than one catalog can be searched, and that other constraints can be included.

Search By Right Ascension

and

Search By Declination

Both are performed on a J2000 coordinate range, with the equal to or greater than (>=), or equal to or less than (<=) operators on the given limits. They use the same rules on entering positions as for the Cone Search. When both limits are given, the search returns the sources between the limits (i.e., you will see proper results for a search on sources with RA between 23 and 01 hours).

 

Search Results

To submit the search parameters entered in the Advanced Search Parameters fields, click on the Search button.  The sources matching the search parameters are listed below the Search Results header at the bottom (Figure 2.6). The results of a search are displayed read-only in the familiar SCT table format in a Search Results tree structure with the possibility to sort on different columns. Previous searches may be saved in the left-hand column tree for convenience — navigating to a previous search is done by simply selecting that search.  Sources presented in the Search Results can be selected, and added to a personal source catalog using copy/paste, etc.. Search results are cleared when you log out of the SCT or the OPT Suite.

Cone Search Results
Figure 2.6: Advanced Search results using the Cone Search.  This also shows the Flux / Structure information when hovering over DETAILS with a mouse.

 

SCT 1.31 User Interface Update

 

Cone Search Sky Map

New with 1.31 is the ability to create a sky map based upon the cone search RA and Dec positions and search radius in degrees. This is accomplished by checking the catalog you wish to search in the list above the search parameters, then check on the Cone Search. Enter the RA, Dec, and search radius. Then click on the Search button to load the parameters into the Sky Map (Figure 2.7). Then click on the Sky Map icon in the Cone Search box to show the Sky Map (Figure 2.8).

Cone Search Sky Map
Figure 2.7: Cone Search parameters for Sky Map
Cone Search Sky Map Result
Figure 2.8: Sky Map result with information for J0006-0004 (mouse hovering over source in map)

 

Hide Catalogs

With 1.31 you have the ability to hide the catalogs that you find in your tree (left hand column) in order to help with organization. To do this, in the Menu do View → Hide/Unhide Catalogs (Figure 2.9). You will be presented with a list of your catalogs with check boxes. Select the catalogs that you want to hide by clicking in the corresponding box, then click on the Update button (Figure 2.10) Note that the catalogs will still appear at the top of the Search page, so they are not hidden from there.

Hide Menu
Figure 2.9: Hide/Unhide menu option
Hide Tree List
Figure 2.10: List of catalogs to hide/unhide

 

 

Connect with NRAO

The National Radio Astronomy Observatory and Green Bank Observatory are facilities of the U.S. National Science Foundation operated under cooperative agreement by Associated Universities, Inc.